top of page
narda_rgb.jpg

NARDA IDA2

Picture1.png

Frequency range : 9k-6GHz

Picture2.png

Detect, Analyze and Locate RF Signals

Highlights on Narda IDA2

Detect

Picture5.png

Extremely fast with a sweep rate of 12 GHz/s

Picture12.png

Live Spectrum with MAX HOLD on same display helps to detect the burst or intermittence signal. 

Analyze

Picture10.png

Spectrogram ( Level, Frequency, and Time) Analysis 

Picture3.png

Time domain signal analysis

Picture8.png

Power Measurement , and Polarization evaluation

Picture4.png
Picture14.png

Multichannel signal power measurement

Persistence Mode ( Analyze Signal in Signals) 

Locate

Picture7.png

Manual DF ( when equipped with Handheld Directional Antenna)

Picture6.png

Triangulation Technique and Display on the map (Built-in) 

Has Spectrogram or Waterfall function really helpful for interference solving?  

Picture11-1.png

This is what the Spectrogram or Waterfall from some low-end Spectrum Analyzer will look like.

This result becomes totally blur, due to the poor resolution they provided. 

So, it cannot help you when the real situation comes.

Picture11-3.png
Picture11-2.png

This is what Spectrogram from, Narda IDA2 provides you.

A better clear result can display, due to the higher resolution we provided.

So, Narda IDA2 can help you work on the interference issue, effectively. 

Example, Narda IDA2 is handling the issue of an interference signal (at the Marker position) as very sharp and clear result.

​Has anyone in the market prepare the scheme to maintain the measurement accuracy in the Overdrive & Overmodulation environment for you? 

Challenge in nowadays

It is often necessary to measure weak radio signals in the presence of strong radio signals. Analysis of weak radio signals requires high measurement sensitivity, but this requirement rapidly leads to overmodulation of modern measuring receivers and signal analyzers when receiving strong signals at the same time.

Picture13.png

Hence, if we've continued to process the measurement without the appropriated scheme to handle this situation,  then the analyzer shall become a Non-Linearity characteristic, and the measured result shall become invalid accordingly.

Solution

Picture13-1.png
Picture13-2.png

Narda is the only one Test & Measurement vendor in the market who has really care about this issue for the customer. That's why Narda has design the external filters that suitable and can be attached and detached from the analyzer input directly. This shall maintain the accuracy for the measurement during the hard situations in nowadays.

overdrive.PNG

No filter

With filter

Picture13-4.png

All Narda Filters have design and calibrate , appropriately for matching to applied with IDA2.

All Narda filters come with N-connectors (one male, one female) directly mate with the RF cable of the filter mounting kit and with the IDA set. The typical insertion loss of Narda´s filter selection is below 2 dB. The VSWR is typically less than or equal to 1.5:1.

Capture.PNG

Please let KPS working groups help you for more details by contacting us

bottom of page