top of page
The Superb EW/COMINT and Spectrum Monitoring solutions
KPS WORKING GROUPS
NARDA IDA2
Frequency range : 9k-6GHz
Detect, Analyze and Locate RF Signals
Highlights on Narda IDA2
Detect
Extremely fast with a sweep rate of 12 GHz/s
Live Spectrum with MAX HOLD on same display helps to detect the burst or intermittence signal.
Analyze
Spectrogram ( Level, Frequency, and Time) Analysis
Time domain signal analysis
Power Measurement , and Polarization evaluation
Multichannel signal power measurement
Persistence Mode ( Analyze Signal in Signals)
Locate
Manual DF ( when equipped with Handheld Directional Antenna)
Triangulation Technique and Display on the map (Built-in)
Has Spectrogram or Waterfall function really helpful for interference solving?
This is what the Spectrogram or Waterfall from some low-end Spectrum Analyzer will look like.
This result becomes totally blur, due to the poor resolution they provided.
So, it cannot help you when the real situation comes.
This is what Spectrogram from, Narda IDA2 provides you.
A better clear result can display, due to the higher resolution we provided.
So, Narda IDA2 can help you work on the interference issue, effectively.
Example, Narda IDA2 is handling the issue of an interference signal (at the Marker position) as very sharp and clear result.
Has anyone in the market prepare the scheme to maintain the measurement accuracy in the Overdrive & Overmodulation environment for you?
Challenge in nowadays
It is often necessary to measure weak radio signals in the presence of strong radio signals. Analysis of weak radio signals requires high measurement sensitivity, but this requirement rapidly leads to overmodulation of modern measuring receivers and signal analyzers when receiving strong signals at the same time.
Hence, if we've continued to process the measurement without the appropriated scheme to handle this situation, then the analyzer shall become a Non-Linearity characteristic, and the measured result shall become invalid accordingly.
Solution
Narda is the only one Test & Measurement vendor in the market who has really care about this issue for the customer. That's why Narda has design the external filters that suitable and can be attached and detached from the analyzer input directly. This shall maintain the accuracy for the measurement during the hard situations in nowadays.
No filter
With filter
All Narda Filters have design and calibrate , appropriately for matching to applied with IDA2.
All Narda filters come with N-connectors (one male, one female) directly mate with the RF cable of the filter mounting kit and with the IDA set. The typical insertion loss of Narda´s filter selection is below 2 dB. The VSWR is typically less than or equal to 1.5:1.
Please let KPS working groups help you for more details by contacting us
bottom of page